Virto.CAD Version 1.11.3

We hereby introduce Virto.CAD version 1.11.3. Please continue reading for an overview about the new features, improvements and bug fixes.

New features and improvements

  • Cross section: allows users to visualize the intersection of drawn lines with panels, terrain objects, and 3D obstacles.
  • Ground clearance visualization: now displays a warning message and highlights racks with an exclamation icon if they clash with the ground.
  • Build rooftop layout (EW/S): users can now directly select mounting system presets within the build window.
  • Compass linking: we simplified linking of multiple layout boundaries to the same compass. Selection of a compass in a dropdown now applies it to all selected boundaries.
  • Sunbeam Supra:
    • Sunbeam Supra now supports Sweden, Finland, Poland and Switzerland.
    • We added BOM report option.
    • Sunbeam product is now automatically selected on the Mounting Systems ribbon based on the preset used.
  • Esdec/CPX:
    • Now supports Denmark, Finland, Norway and Poland.
    • Project information grouped to the separate window.
    • Wind zone/speed dropdown has been removed for non-relevant countries.
  • Ballast calculation:
    • Ballast BOM and Report are now saved directly on the computer, reducing the size of DWG files.
    • Ballast calculation now checks if the boundary is fully placed inside the rooftop.
  • Civil works: "keep out" zones can now be placed around roads.
  • Label tag composer: users can now set string label text height after strings are placed (both center and polarity).
  • Device placement:
    • Manual device placement process has been optimized for speed.
    • Distance between devices now considers the actual distance between their sides instead of their centers.
  • String mapping:
    • "Change row connection" command is now available for ground projects.
    • Improved performance of manual string mapping.
    • We added ability to swap polarities of selected strings using string mapping commands.
  • Build ground layout: inter row distance input box is now separated into "Min" and "Max".
  • Wiring groups:
    • Wiring groups are now copied along with panels.
    • Optimization of wiring group name placement.
  • Summary palette: displays a warning message if an empty table is inserted from the summary palette.
  • Ground clearance visualization: we changed the order of the sections to be more logical: now the user first selects the boundaries, and after that picks the heights and colors.
  • Calculate DC cables: we removed 2.5mm² cable option.
  • String settings: "Polarity offset" setting now supports decimal numbers.
  • PVsyst export: we improved the accuracy of the PVsyst export.
  • Layout boundary: enhanced performance of boundary recovery feature.

 Bug Fixes

  • String mapping: we...
    • Fixed a bug where String Mapping Automatic (roof): Highlight mapping is not executed at the end.
    • Resolved several bugs related to incorrect polarity placement of string mapping when using the string mapping type 'crossing'.
    • Fixed a bug where strings sometimes had more interconnections than they should.
    • Fixed a bug where string navigation was incorrect when the System configuration contained YConnectors.
  • Database: we fixed a bug where the filter dropdown in the inverter database could have duplicated values.
  • System config:
    • Device allocation to the wiring groups is now almost immediate (as well as de-allocation).
    • We fixed a bug where the correct amount of inputs couldn't be added to the string box.
  • Irradiance simulation: we fixed a bug with negative percentage while calculating surface irradiance.
  • Numbering: we fixed a bug where Numbering gave weird results in some places.
  • BricsCAD: We...
    • Fixed a bug where BricsCAD randomly crashed during some operations.
    • Addressed several discrepancies between AutoCAD and BricsCAD UIs.
    • Fixed a bug that often crashed BricsCAD when some auxiliary windows were closing or opening.
    • Fixed a bug where closing the CAD application when the mounting system BOM panel was opened could break the CAD ribbon during the next launch.
    • Fixed a bug where opening BricsCAD threw errors on V24.2.03.
  • Ground clearance visualization: we fixed a bug where “Select all” and “apply” threw an
  • Build ground layout: we fixed a bug where trackers built with high shadow angles led to incorrect results.
  • Rebuild Ground: we removed the "Continuous numbering" option from the "Rebuild ground" window.
  • Summary palette: we fixed a few row misalignments in the AC devices table.
  • Calculate DC cables: we...
    • Fixed a bug where not the most optimal cable was chosen.
    • Fixed a bug where NEC cable voltage drop was incorrectly calculated in the summary palette.
  • Bill Of Materials (BOM): we fixed a bug where opening the BOM crashed AutoCA
  • Sunbeam: we...
    • Fixed a bug where Dilatation Validation did not run when the window was opened.
    • Fixed a bug where the roof zone failed to place.